Scope of Supply: Pump Service
–Field Site Service

In 2013, Western Energy was awarded by SMM to overhaul the two unit of Arai HTS Transfer Pumps
Tag No.: P-1052; Model: 100KNV-293 & Tag No. P-1053, Model : 80KNV-232.
Findings: Pump Shaft Run-out was carried out and shaft as found
Repair Job: Bend pump Shaft was straightened back to within tolerance.
End User: SINGAPORE METHYL METHACRYLATE PTE LTD
–Pump Was Sized And Burnt.
Overhaul Job from SMM for Arai Pump Tag No.P-8010S, Model: 40APV-81, SN: 55-K200S
Findings: Pump shaft was found badly seized journal bearing area during pump dismantling.
Result: Heat was applied on the journal bearing area but pump shaft just do not move. SMM decide to order a new shaft for replacement.
End User: SINGAPORE METHYL METHACRYLATE PTE LTD
Pump was re-assembled to good order as per manual instruction.